19'' 6U Chassis page 20/71
...\microsens\moduleMS430601M\ms430601mcontrolsWrite\ms430601mCtrlLine\
ms430601mCtrllineSfpOnOffCtrlTable\
• Remove the Fibre Optic connector
• Release the SFP by: Carefully opening the latch or pressing the locking
button and slide the SFP out of the module and place it aside
• Gently push the SFP into the relevant module port until it is securely seated.
Take care to insert the SFP respecting the orientation described in the
following picture
Do not remove the protective caps from the SFP until you are ready to attach
the fibre-optic.
• Clean Fibre Optic connectors on fibre optic cable
• Re-connect Fibre
• Verify correct operation of the SFP
End procedure
XFP Replacement Procedure
The Line port has two LEDs located on the front panel of the MS; LOS and Fail,
indicating operating status of each of the ports. If a Line port XFP needs to be replaced
use the following procedure:
Procedure
The following procedure describes how replacing an XFP on a MS43062XM.
The XFP ’s are hot-swappable therefore there is no requirement to power down the
Module.
• Ensure that the correct module is selected for management. Consult the
object:
mgnt2GigmSelectedBoard
Location:
..\microsens\mgnt2\mgnt2SNMPAgentData\mgnt2ModulesManagement\
• Change if necessary
• Refresh the module inventory setting the following object:
ms43062XMRinvReloadInventory
Location: ...\microsens\moduleMS43062XM\ms43062XMri\