Fast Ethernet Switches for Industrial Use Page 8/10
MICROSENS GmbH & Co. KG - Kueferstraße 16 - 59067 Hamm / Germany - Tel. +49 23 81/94 52-0 - FAX -100 - www.microsens.com
Power supply / Alarm Contact
The power supply is done by an external power supply with an output voltage of 12 - 48
V DC. The power supply unit is not included at delivery, but can be ordered separately
(e.g. MS700420 24 V DC/24 W). The connection is done by the pluggable screw terminals
on the top of the device. The connection of a redundant power supply can be done by
the second screw terminal. In the following drawing the pin out of the power connector
and the alarm contact is described.
Fig. 6: Pin out Power Connector and Alarm Contact
The alarm contact is normally closed and opens if power input 1 or 2 fails.
Fiber Connections
The 4x 10/100TX + 1x or 2x 100FX Industrial Switch has the SC type (optional ST) fiber
port using in Multimode (2km) or Single Mode (30km). When you connect the fiber port
to another one, please follow the below figure to connect it. Wrong connection will not
allow the port to work normally.
Fig. 7: Connecting the Fiber Ports