19'' 6U Chassis page 14/71
The rescue CLI allows the user to perform all the upgrade procedure described in the
CLI documentation.
Use the following procedure to start the rescue CLI on the MGNT management board:
Procedure
Use a needle-like tool (i.e. paper clip) to reach the MGNT reset button and
press during 5 seconds minimum to activate the rescue CLI feature
Observe behaviour of MGNT LEDs. The colour sequence of the SW LED on the
front panel of the MGNT is: Green > Off > Orange > Green
The rescue CLI is then available through the RS232 port
Use the login “administrator” and the password “administrator” to log in
the rescue CLI
The prompt “rescue_cli>” appears to indicate that the rescue CLI is currently
running
You can perform all the required upgrade or change the configuration of the
MGNT management board
Perform a reset of the MGNT management board to quit the rescue CLI
End procedure