Microsens RS232 Spécifications Page 26

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 36
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 25
4 Port Industrial Device Server Manual page 26/36
MICROSENS GmbH & Co. KG - Küferstraße 16 - 59067 Hamm - Tel. +49 2381/9452 0 - Fax 9452 100 - www.microsens.com
The following table describes the labels in this screen.
Label
Description
Port Alias
Remark the port to hint the connected device.
Interface
RS232 / RS422 / RS485(2-wires) / RS485(4-wires)
Baud rate
110bps/300bps/1200bps/2400bps/4800bps/9600bps/19200bps/
38400bps/57600bps/115200bps/230400bps/460800bps
Data Bits
5, 6, 7, 8
Stop Bits
1, 2 (1.5)
Parity
No, Even, Odd, Mark, Space
Flow Control
No, XON/XOFF, RTS/CTS, DTR/DSR
Force TX Interval
Time
Force TX interval time is to specify the timeout when no data has been
transmitted. When the timeout is reached or TX buffer is full (4K
Bytes), the queued data will be sent. 0 means disable. Factory default
value is 0.
Performance
Throughput: This mode optimized for highest transmission speed.
Latency: This mode optimized for shortest response time.
Apply
Activate settings on this page.
Port Profile
The following table describes the labels in this screen.
Vue de la page 25
1 2 ... 21 22 23 24 25 26 27 28 29 30 31 ... 35 36

Commentaires sur ces manuels

Pas de commentaire